Engineering Plastics

Oil Filled Nylon 6

Oil Filled Nylon

Oil filled nylon offers the following benefits over standard nylon:

• Reduced coefficient of friction (up to 50%).
• Increased wear resistance (up to x10).

Temperature: -40°C to +100°C, +160°C short term.

Applications: Ideal for unlubricated, highly loaded and slow moving parts.

Availability:

Colour:  Green. 
Sheet Size (mm):  2000 x 1000. 
Thickness (mm):  10 to 50.
Rod dia (mm):  4 to 500.
Length (mm):  3000. 

Technical Specification:

Information to be used as a guide only. It corresponds with our current knowledge and indicates possible applications. We cannot guarantee suitability for a specific application. Unless otherwise stated these values represent averages taken from injection moulded samples.


 

Product  Test Method  Notes  Metric Units Imperial Units 
Density  ISO 1183:1987  Test Method A  g/cm3  1.140  lb/inch3  0.041
Moisture Absorption (Saturation)  ISO 62:1999  Immersion 23ºC  4
Mechanical 
Tensile Strength  ISO 527-1/2:1993  Sample 1B, 50mm min -1  MPa  75  psi  10878
E-Modulus  ISO 527-1/2:1993  Sample 1B, 50mm min -1 MPa  3800  psi  551145
Elongation at Break ISO 527-1/2:1993 Sample 1B, 50mm min -1 % >25 % >25
Compressive Strength ISO 604:2002 Sample Type B, 5mm min -1 MPa 95 psi 13779
Compressive Modulus ISO 604:2002 Sample Type A 1mm min -1 MPa 2400 psi 348091
Flexural Strength ISO 178:2001 1.5mm min -1 MPa 95 psi 13779
Flexural Modulus ISO 178:2001 1.5mm min -1 MPa 3000 psi 435114
Izod Impact Strength ISO 180:2000 Sample Type A (notched) KJ/m2 5.80 ft.lb/in2 2.76
Hardness Shore D ISO 868:2003     83   83
Coefficient of Friction (Dynamic)   31.4m/min, 1.75MPa   0.19   0.19
Wear Rate   31.4m/min, 1.75MPa mg/km  0.15    
K-Factor   31.4m/min, 1.75MPa mm3/Nm 1.70 x 10-6 in3.min./ft.lb.hr 0.84 x 10-9
Thermal
Melting Temperature     ºC 220 ºF 428
Maximum Intermittent Service Temperature     ºC 170 ºF 338
Maximum Continuous Service Temperature     ºC 110 ºF 230
Minimum Intermittent Service Temperature     ºC -100 ºF -148
Minimum Continuous Service Temperature     ºC -40 ºF -40
Coefficient of Linear Thermal Expansion (TMA) ISO 11359-2:1999 23ºC - 55ºC ºC-1 8 x 10-5 ºF-1 4.44 x 10-1
Flammability IEC 60695-11-10:2003     HB    HB
Electrical
Dielectric Constant IEC 60250:1969-01 1MHz   3.7   3.7
Dielectric Strength IEC 60243-1:1998-01   kV/mm 25 kV/In 635
Volume Resistivity IEC 60093: 1980-01   ohm.m 1 x 1013 ohm.in 3.93 x 1014
Surface Resistivity ROA IEC 60093: 1980-01   ohm 1 x 1012 ohm 1 x 1012
Comparitive Tracking Index IEC 60112:2003-01   CTI 600 CTI 600

The information shown above corresponds with our current knowledge of our products. We accept no responsibility in respect of application, conversion or use made of our products.
 
 