Engineering Plastics

Makrolon® Polycarbonate Sheet

Makrolon Polycarbonate Sheet

Makrolon® UV is made from clear-transparent polycarbonate with UV protection on both sides. They are the perfect choice for a long service life owing to their good weathering resistance. These attributes are backed up by our 10-year guarantee on weathering resistance and a 10-year guarantee on retaining their mechanical properties.

Benefits:

• Excellent weathering resistance

• Extreme impact strength

• Good fire rating

• Thermoformable

Applications: ideal for outdoor applications, covered walkways and bus shelters, barrel vaults and skylights (also thermoformed)

Availability:

Thickness (mm) 2mm up to 12mm
Sheet sizes (mm) 2050x1250, 3050x 2050, 6110x 2050
Colour clear 2099, white 2130, white 2150, bronze 2850, grey 2760, blue 2550, green 2650

 Sheet size may depend on colour.  Other sizes, colours and sheet thicknesses on request

Technical Specification

Test Conditions Typical  Values Unit Test Method
PHYSICAL        
 Density    1.2  g/cm3  ISO 1183-1 
 Moisture absorption storage in std climate 23ºC/50% RH
storage in water 23ºC saturation

 0.15
 0.35


 %
 %

 ISO 62-4
 ISO 62-1
 Refraction index 20ºC  1.586  -  ISO 489
       
MECHANICAL        
 Tensile stress at yield    >60   MPa  ISO 527-2/1B/50
 Elongation at yield    6  %  ISO 527-2/1B/50
 Tensile strength    >60  MPa  ISO 527-2/1B/50
 Elongation at break    >70  %  ISO 527-2/1B/50
 Elastic modulus    2400  MPa  ISO 527-2/1B/1
 Limiting flexural stress    ca. 90  MPa  ISO 178
 Impact strength  Charpy, unnotched  no break  kJ/m2  ISO 179/1fU
   Charpy, unnotched  ca. 11  kJ/m2  ISO 179/1eA
   Izod, notched  ca.10  kJ/m2  ISO 180/1A
   Izod, notched  ca.70  kJ/m2  ISO 180/4A
THERMAL        
 Vicat softening temperature  Method B50  148  ºC  ISO 306
 Thermal conductivity    0.2  W/m ºC  DIN 52612
 Coeff. of linear thermal expansion    0.065  mm/m ºC  DIN 53752-A
 Heat deflection temperature under load  Method A: 1.80 MPa
 Method B: 0.45 MPa
 127
 139
 ºC
 ºC
 ISO 75-2
 ISO 75-2
         
ELECTRICAL        
 Dielectric strength    35  kV/mm  IEC 60243-1
 Volume resistivity    1016  Ohm.cm  IEC 60093
 Surface resistivity    1014  Ohm  IEC 60093
 Dielectric constant  at 103 Hz
 at 106 Hz
 3.1
 3
   IEC 60250
 IEC 60250
 Dissipation factor  at 103 Hz
 at 106 Hz
 0.0005
 0.009
   IEC 60250
 IEC 60250

The mechanical properties were measured on sheets of 4mm or 3mm thickness.

Product Liability Clause: This information and our technical advice – whether verbal, in writing or by way of trials – are given in good faith but without warranty, and this also applies where proprietary rights of third parties are involved. Our advice does not release you from the obligation to verify the information currently provided – especially that contained in our safety data and technical information sheets – and to test products as to their suitability for the intended processes and uses. The application, use and processing of our products and the products manufactured by you on the basis of our technical advice are beyond our control and, therefore, entirely your own responsibility. Our products are sold in accordance with the current version of our General Conditions of Sale and Delivery.

Light Transmission:

Test Method according to DIN 5036 The stated thicknesses are not all available as standard. Please ask us for more information. The stated values are typical values only.

 

Thickness (mm)

 Light transmission in %  2  3   4   5   6     10   12   
 Makrolon® UV clear 2099  88  87  87  86  85  84   82   81   
 Makrolon® UV white 2130  40  30  23  18  13        
 Makrolon® UV white 2150  60  50  40  33  28  20      
 Makrolon® UV bronze 2850  63  50  50  50  50  50  42  36  
 Makrolon® UV grey 2670    62  55  49  43  34  26    
 Makrolon® UV green 2650    77  73  71  68  62      
 Makrolon® UV blue 2550    61  55            

Fire Rating (*)
Oxygen index (LOl) 28% ISO 4589-2 Method A.

 Country  Standard   Rating   Thickness  Colour 
 Germany  DIN 4102   B2  ≥ 0.75 mm   all colours 
 U.K.  BS 476 Part 7  1Y  2,4,6,8, & 12 mm  clear 2099
 France  NFP 92-501 & 505  M2   2-12mm  clear 2099
     M2  2-12mm  white 2130
     M2  2-12mm  bronze 2850
   NFP 16-101 & 102  F1   2-12mm  clear 2099
     F1  2-12mm  white 2130
 Italy  CSE RF 2/75/A  Classe 1   2-10 mm roof  all colours
     Classe 1  2-6 mm wall  all colours

Glow wire flammability index, IEC 60695-2-12, in °C (*)

 

Thickness

 Grade    3  4   5  6
 Makrolon® UV clear 2099  800    960    960
 Makrolon® UV bronze 2850    960  960    
 Makrolon® UV white 2130  960  960  960    
 Makrolon® UV white 2150    960  960  960  960
(*) fire certificates are limited in time, always check if the mentioned certificate is still valid

Weathering Resistance:

Makrolon® UV sheets show excellent weathering resistance, which guarantees their impact strength even after many years. Since their introduction in 1989, the sheets have been examined in an intensive test program, including a real-time outdoor exposure test in a southern European climate (Bandol) and in hot and humid regions (Florida and Singapore). The sheets are provided with a 10-year warranty on unbreakability and on optical properties.

Permanent Service Temperature:
The permanent service temperature without load is approx. 120°C.

 

BACK

Manufacture, process and supply
plastic, insulation and rubber products to industry

Banner Image